Your thermostat has an "emergency heat" setting, and on a cold Iowa morning it's worth knowing what flipping it to EM HEAT actually does. It shuts off your heat pump's outdoor unit and switches your system to backup heat only, usually electric strip heat inside the air handler. It's meant for when the heat pump itself has stopped working, not as a way to help it along when it's cold out.
That matters here because gas is how most Iowa homes heat, so if your backup heat is electric resistance instead of a furnace, running on emergency heat for any length of time will show up on your bill fast. Power is cheap in Iowa, but electric strip heat is still a far more expensive way to heat a house than either a gas furnace or a heat pump running normally.
If your heat pump is icing up badly, short cycling, or not keeping the house warm even with the outdoor unit running, that's usually a sign of a real problem, not a reason to leave it on emergency heat all winter. A stuck reversing valve, a failing defrost control, or a low refrigerant charge can all cause this, and none of them fix themselves.
Figuring out which one it is means having someone look at the actual unit outside your house. If you'd rather not guess, the next step here is getting matched with a local contractor who works on heat pumps in Iowa winters and knows what tends to go wrong with them this time of year. You'd hear from one contractor, not several, and they'd be looking at your system specifically, not quoting you blind. From there, the button below is where that starts.
What does emergency heat mean on my heat pump?
Your thermostat has that EM HEAT setting and you're not sure what it actually changes. Maybe the heat pump is icing up, maybe it's just not keeping the house warm enough on a cold morning, and you flipped the switch to see if it would help. Before you leave it there, it helps to know what's actually running in your system when that setting is on.
Emergency heat shuts off the heat pump and runs on backup heat alone
When you switch to EM HEAT, the outdoor unit stops completely and your system heats the house using backup heat only, which in most homes is electric strip heat built into the air handler. Normally that backup only kicks in to help the heat pump on the coldest days. On EM HEAT it does all the work by itself. That setting exists for when the heat pump itself can't run, usually because of a mechanical problem or ice on the outdoor coil that isn't clearing on its own. It's not meant to be left on through a cold snap. Since power here is cheap, running on electric strip heat for a short stretch won't hit you hard, but if the outdoor unit isn't running, something needs a look before the weather turns colder.




Thermostat sends a signal to shut off the outdoor compressor unit.
Heat pump stops pulling any heat from the outside air.
Backup electric strip heat kicks on inside the air handler.
Strip heat warms the air without the outdoor unit running at all.


Power costs 13.62 cents per kilowatt-hour statewide
At 13.62 cents a kilowatt-hour, running on strip heat costs real money fast, since that backup heat draws far more power than the heat pump itself. Leaving your thermostat on EM HEAT overnight or for days at a time shows up on your next bill.
EIA-861 2025 statewide residential average

It's January, past midnight, and you're standing in the hallway in your socks because the bedroom down the hall feels wrong. Your daughter kicked off her blanket an hour ago and the air coming through the vent isn't warm, just moving. You check the thermostat in the hall and see EM HEAT lit up on the display, a setting you don't remember choosing. The furnace sounds like it's working. The house isn't getting warmer. You pull the blanket back over her shoulders and stand there a minute, listening to the air handler run, trying to decide if this is something that fixes itself by morning or something you need someone to look at before the weekend.
A local pro for your heat pump repair
A heat pump stuck on emergency heat isn't fixing itself, and it isn't supposed to run that way for long. Most Iowa homes heat with gas furnace backup or electric strip heat for exactly these cold mornings, not as the everyday plan. If your outdoor unit is icing up, short cycling, or just won't shut off that EM HEAT light, something in the system needs a look, whether that's a stuck reversing valve, a failed sensor, or low refrigerant. A local contractor who works on heat pumps all winter here has seen that thermostat flipped to EM HEAT plenty of times, and knows what usually causes it in this climate. Getting matched with one tech means you explain the problem once, to someone who shows up already knowing what questions to ask about your system. That beats guessing at it yourself while your bill climbs.
EM HEAT for a few hours during an ice storm or a repair visit is what the setting is for, and your system is built to handle that without trouble.
EM HEAT left on for a week because nobody noticed is strip heat carrying the whole house, and that's the bill a working heat pump would never run up.


Why is the house in EM HEAT and nobody switched it
Walk past the thermostat and check if EM HEAT has been lit up longer than you remember setting it. Air out of the vents feels hot to the touch instead of the milder warmth a heat pump puts out, and the outdoor unit sits quiet and still even on a cold afternoon when it should be running. Sometimes it's not a flipped switch at all. The heat pump itself may have locked into backup heat on its own because of ice on the outdoor coil or a part that failed, and strip heat is carrying the whole house without you ever touching the thermostat. Either way, the longer it runs like that, the more it costs you, and a system that switched itself over is telling you something needs a look before the next cold snap.

Why it ices up in the first place
Cold, damp air is normal for a heat pump to pull heat from, and frost builds on the outdoor coil most mornings in an Iowa winter. The unit runs a defrost cycle to melt it off, then goes back to normal. If that coil stays frosted over or turns to a solid sheet of ice, the unit can't pull heat anymore, and that's when a thermostat gets switched to EM HEAT.

What strip heat is actually doing
The strip heat inside your air handler works like a toaster. Metal coils heat up when power runs through them, and a blower pushes air across those coils and out through your ducts. There's no outdoor unit involved and no refrigerant moving. It's simple, it's reliable, and it's the reason the air coming out feels hotter than what your heat pump normally puts out.

Your heat pump isn't broken, but something made it give up
A heat pump switches itself to emergency heat when something stops it from pulling warmth from outside air. Maybe the outdoor fan quit, maybe the coil iced over and never cleared, maybe a sensor is telling the system something's wrong even when it isn't. Either way, the house stays warm while the real problem sits there unfixed, because strip heat doesn't care what's wrong with the outdoor unit. It just takes over.
That's the part worth catching early. A heat pump that keeps tripping into EM HEAT on its own, especially on mornings that aren't that cold, is telling you something failed out there. A contractor who works on heat pumps through an Iowa winter has seen most of what causes this and can usually tell within a few minutes of looking at the outdoor unit whether it's a sensor, a motor, or ice that isn't melting off like it should.


Summer here isn't just hot, the air sits heavy, with dew points averaging 62°F across June, July and August according to NOAA climate data. That's the same heat pump that ices up on a January morning, and in July it's pulling moisture out of thick air instead of cold out of it. Humid air makes the outdoor coil work harder to shed heat, and a system that's already strained shows it in summer too, not just in winter. If the house feels sticky even with the thermostat satisfied, or the unit runs long stretches without catching up, that's the same equipment under a different kind of load.
NASA POWER T2MDEW county cells weighted by homes
EM HEAT on your thermostat is backup heat, running without the outdoor unit, and it's meant for a cold snap or a repair visit, not for the whole winter. If it's been lit up for days and nobody flipped it on purpose, something stopped your heat pump from pulling heat the way it's supposed to, and that's worth a look before the next bill shows what strip heat actually costs. A contractor local to Iowa who services heat pumps all winter has seen this before, knows what tends to fail when a system falls back to emergency heat, and can tell you in one visit whether it's the outdoor fan, a frozen coil, or a sensor telling the system something that isn't true. You'll be matched with one contractor, not a handful calling you back at once, so the person who shows up already knows what they're looking at. Your heat pump switching to EM HEAT isn't the house failing you in the middle of winter. It's the system telling you where to look.

Get the right pro for your heat pump
The pro who reaches out is licensed in Iowa.