Your heat pump shows "aux heat" on the thermostat and you're not sure if that's normal or if something's wrong. Most of the time it's doing exactly what it's supposed to. When the temperature outside drops low enough, a heat pump can't pull enough warmth from the air to keep up, so a backup heat source kicks in to cover the gap. In Iowa that backup is usually electric resistance coils, or it ties into the gas furnace if your home has one set up that way.
Seeing aux heat on a cold January morning isn't a problem. Seeing it run on a mild fall day, or seeing it stay on for hours instead of cycling off, is worth paying attention to. That usually points to something keeping the heat pump itself from doing its job, a low refrigerant charge, a frozen outdoor coil, or a thermostat set wrong for how the system is wired.
Since power is cheap here, a heat pump leaning on electric aux heat more than it should won't always show up fast in a bill. That makes it easy to miss for a while. Gas furnace backup makes the extra runtime easier to notice, but either way, the fix isn't something to work out yourself from the thermostat display.
If you're seeing aux heat more than seems right for the weather, the next step is getting someone who works on heat pumps regularly to look at yours specifically, your system, your wiring, your setup. Once you send the details through, that part stops being on you. A contractor who covers your area gets your information and reaches out to you directly. No guessing which company to call or whether they work on your type of system. You just wait to hear back.
Auxiliary heat is the backup heater built into your system that kicks in when the heat pump alone can't keep up with the cold. In Iowa, that happens on the coldest days of winter, when outdoor temperatures drop low enough that the heat pump can't pull enough warmth from the outside air to match what the thermostat is asking for. The system switches on the backup heat, usually electric resistance coils, to make up the difference. You might also see it turn on during defrost cycles, when the outdoor unit melts ice off its coils and needs help keeping the house warm in the meantime. Seeing "aux heat" on the display during a cold snap is normal. What's worth watching is if it stays on for long stretches when it isn't that cold out, or runs constantly instead of cycling. That pattern usually means the heat pump itself isn't working the way it should.


Your heat pump doesn't make heat the way a furnace does. It moves heat that's already in the outside air into your house. That works fine most of the year, but Iowa winters push outdoor air cold enough that there's not much heat left out there to grab. The colder it gets, the harder the system has to work to pull in what's left. When it can't close the gap between the house temperature and what the thermostat is asking for, the backup heat switches on. That backup is usually electric strips inside the air handler, the same idea as a toaster, glowing hot when current runs through them. You'll also see aux heat kick in for a few minutes during a defrost cycle, when the outdoor unit runs cold air through itself to clear off frost and needs something to cover the house while it does. None of that costs anything to run most days. Electric strips don't get a boost from outside air like the heat pump does, so they use more power per hour whenever they're on.
How Aux Heat Actually Works
- A heat pump moves heat from the outside air into your house rather than burning fuel to create it.
- As the outdoor temperature falls, the outside air holds less heat for the system to pull inside, so it has to work harder to keep up.
- Auxiliary heat is usually electric resistance heat, strips of wire inside the air handler that glow hot like a toaster when current runs through them.
- The thermostat calls for aux heat when the heat pump alone can't close the gap between the house temperature and the set temperature.
- A defrost cycle also brings on aux heat for a few minutes, since the outdoor unit runs cold air across itself to melt frost and needs backup warmth while it does.
- Because aux heat runs on electricity with no boost from the outside air, it costs more to run per hour than the heat pump alone.




A pro who works on heat pumps
If aux heat is stuck on and the house still feels cold, that's not a backup heater problem anymore, that's the heat pump not pulling its weight. Most homes around here lean on gas furnaces, so when a heat pump is involved it's usually paired with one, and a heat pump that can't keep up pushes the whole system to lean harder on the furnace side than it should. That shows up on the gas bill even with power as cheap as it is here. A low refrigerant charge, a failing compressor, a frozen outdoor coil, any of those can force aux heat to run far more than a cold morning calls for. Figuring out which one it is means getting eyes on the system, not guessing from the thermostat. Once you send the request, you're not the one tracking down who's available or chasing a callback. That part is off your plate.
Power is cheap in Iowa, but electric resistance heat still costs more to run than the heat pump's compressor, so a few hours of aux heat on a cold morning barely registers.
If aux heat is running for hours instead of minutes, that difference shows up fast on the bill, and it usually means the heat pump needs a look before the next cold snap.


Normal Aux Heat or a Problem
Normal aux heat
- Comes on during a cold snap, usually when the morning temperature drops into the teens or lower.
- Runs for a short stretch, then shuts off once the house reaches the set temperature.
- Shows up after you bump the thermostat up several degrees at once, since the heat pump alone can't catch up that fast.
- The house warms at a normal pace and holds steady once it gets there.
- Cycles with the heat pump rather than replacing it, so both are working together.
Aux heat problem
- Runs for hours at a stretch instead of cycling off once the house warms up.
- Stays on even on milder days, when the heat pump should be handling the load by itself.
- The house still feels cold or won't hold the set temperature despite aux heat running.
- The outdoor unit isn't running at all, or you can't hear it kick on like it used to.
- Shows up alongside a spike in the electric bill, since resistance heat costs more to run than the compressor.

Summer here isn't just hot, it's heavy. NOAA puts the average summer dew point across Iowa at 62°F, which is the sticky, sit-on-your-chest kind of humid. Your heat pump works the same way in July as it does in January, just moving heat instead of making it, and that same system has to pull moisture out of the air to keep the house comfortable. That's a steady load on the compressor all summer, separate from whatever aux heat is doing in January. If the house feels damp even with the thermostat satisfied, that's worth having looked at.
NASA POWER T2MDEW county cells weighted by homes
Why does my heat pump switch to aux heat instead of just running longer?
You watch the thermostat switch over to aux heat and wonder why it doesn't just let the heat pump keep running until the house catches up. It seems like it would use less power that way. There's a reason the system makes that call instead of just letting the compressor grind on longer.
Because past a certain point, the heat pump running longer won't get the house any warmer
A heat pump moves a fixed amount of heat per hour no matter how long it runs. Once the outdoor air is cold enough, that amount drops below what the house is losing, so letting the compressor run longer just holds the gap open instead of closing it. The thermostat brings in aux heat to make up that difference, not to speed things up. This usually shows up on the coldest mornings, when outdoor temperatures sit in the teens or lower. If aux heat is kicking in on a mild day, that's not the cold doing it. That points to the heat pump falling short of what it should be able to handle on its own.
Indoor thermostat calls for more heat than the house has
Outdoor sensor confirms the air is too cold to pull heat from
Heat pump signals the control board to bring on backup heat
Electric heat strips or the gas furnace fire to make up the difference
Power costs 13.62 cents per kilowatt-hour statewide
At under 14 cents a kilowatt-hour, running aux heat for an hour or two on a cold morning won't wreck your bill. It's the hours-long runs that cost you, since electric heat strips use far more power than the compressor alone. Watch the duration, not whether it turns on at all.
EIA-861 2025 statewide residential average

Aux heat on your thermostat isn't the problem
Aux heat is supposed to come on when it's cold enough outside. Short runs on a frosty morning, then it shuts off and the house holds its temperature. That's the system working the way it was built to work.
What matters is whether your heat pump still does its share. If aux heat is running for hours instead of minutes, or the house won't warm up no matter how long it runs, the heat pump needs a look before another Iowa winter asks more of it. A contractor who handles heat pumps can check it against what your system is actually doing and tell you if something needs fixing, matched to your setup rather than a guess from the thermostat.