June is when it has to work
Homes here run cooling from June through August, three months a year. Once June starts, your AC is on most days from the start, not easing into it.
Takes about a minute. No obligation.
Homes here run cooling from June through August, three months a year. Once June starts, your AC is on most days from the start, not easing into it.
May is the month before cooling starts in Johnson County. Have your AC looked at then, so it is caught early if something is wrong, before June asks it to run hard.

NOAA nClimDiv, 1991–2020 normals
Johnson County runs its AC about three months a year, June through August.
One visit before summer covers what the season asks of it.



Between visits, keep the area around the outdoor unit clear. Grass clippings, leaves and mulch pulled up against the cabinet block airflow across the coil, and that makes the system work harder than it should. Give it a couple feet of open space on all sides. Inside, check the filter and swap it when it looks gray or clogged. A dirty filter starves the system of airflow, and that can ice up the coil even in the middle of summer. If you notice the vents blowing weaker than usual, or the air not feeling as cold as it should, that's worth a call before it turns into a no-cool day.
Half the homes in Johnson County were built in 1992 or later, so a lot of the AC units running here are still well within their working life. A yearly check is what keeps a newer system that way.
Find a contractorA system due for a check rarely tells you with a warning. The signs are smaller than that. Listen for it running longer than it used to before the space feels cool, or cycling on and off more often than it needs to. Watch for ice on the copper line running to the outdoor unit, which means airflow or refrigerant is off even though the system is still trying to work. Notice if one room has gone warmer than the rest of the house, which often points to the blower or the ductwork rather than the outdoor unit itself. A burning or musty smell when it kicks on is worth attention right away, not next week. None of these stop the system outright. They just mean it's working harder to do less, and a check now catches that before the compressor is the one paying for it.
Every bit of dust that doesn't stop at the filter ends up on the coil instead. Once it's packed onto the coil fins it won't wipe off like it would from the filter, and it stays there holding heat against the metal until someone cleans it off by hand.
Warm air gives up its moisture on the coil, and that water is supposed to run out through the condensate drain. Algae and dust build a clog there the same way they would in any small drain line. When it backs up, the water has nowhere to go but into the pan and then onto the floor around the unit.
A tune-up checks the refrigerant charge, cleans the coils, tests the capacitor and tightens the electrical connections.
A tune-up starts with the coil and the filter, but it doesn't stop there. The tech checks refrigerant charge against what the system is supposed to carry, not just whether it's low, because overcharged is its own problem and causes its own wear. The capacitor gets tested, not eyeballed, since a weak one can still start the compressor and still be close to failing. Electrical connections get tightened, because a loose connection generates heat right at the lug, and that heat is what burns wires over time. The blower wheel gets checked for dust buildup, since a dirty wheel moves less air even when the motor behind it is fine. Contacts that have to switch the system on and off get inspected too, because a pitted contact can stick or fail to close at all.