June is when weak units show up
A heat pump sits idle from September to June before it has to carry a full cooling load. A capacitor or contactor that was already marginal often won't make it through that first stretch of heat.
Takes about a minute. No obligation.
A heat pump sits idle from September to June before it has to carry a full cooling load. A capacitor or contactor that was already marginal often won't make it through that first stretch of heat.
Heat runs here from October through May, eight months against four for cooling. A heat pump struggling at the start of October is likely to keep struggling through the months that follow.

NOAA nClimDiv, 1991–2020 normals
An old compressor and a cracked heat exchanger are not the same kind of bad news.
One is a repair bill, the other is the reason to start pricing a new system instead.




Warren County sees its share of hail and wind, but none of that reaches the parts inside the cabinet. The number worth knowing is 17 degrees, the average overnight low here across December, January and February. That's a normal Midwest winter, not an extreme one, and a heat pump built for this climate is built to handle it. So a unit struggling on a 17-degree night isn't being asked to do something unreasonable. It's more likely a weak capacitor or a reversing valve that was already on its way out before the cold had anything to do with it.
If your heat pump came with the house, check how old that makes it. A system installed within the last decade or two hasn't had the time to wear into the kind of failure that calls for replacement, so the usual answer is to repair it and move on.
Find a contractorBefore anyone comes out, there are a few things worth checking yourself. Look at the thermostat first. Make sure it's set to heat or cool as needed and the temperature is actually calling for one. A dead thermostat display usually means a tripped breaker or a blown fuse, and that's worth checking at the panel before anything else. Look at the outdoor unit. If the coil is covered in ice or buried in leaves and debris, airflow is blocked and the system can't do its job. Check the air filter inside. A filter clogged with dust chokes the system the same way a blocked outdoor coil does, and it's the easiest thing on this list to fix yourself. If the system runs but the air doesn't feel like it's doing anything, that's different from a system that won't run at all, and it's worth telling the tech which one you've got before they arrive.
Everything else in a heat pump is the same as an air conditioner, but the reversing valve is what lets it run backward and pull heat from outside air in the winter. When it sticks, the system can get stuck in one mode, blowing cold air when it should be heating, or it won't defrost properly. A stuck reversing valve is one of the few failures that's particular to a heat pump rather than something it shares with a straight AC system.
A capacitor weakens over years of starting the compressor and fan motor, and eventually it can't deliver the jolt either one needs to start. A contactor's contacts pit and burn from years of making and breaking that same connection until it stops closing reliably. Both are small, both are common points of failure, and neither has anything to do with the refrigerant side of the system.
A heat pump that's struggling still gets asked to run, and that's what turns a small problem into a bigger one. A weak capacitor forces the compressor to pull extra current every time it tries to start. It might start anyway, again and again, and each hard start adds wear to the compressor windings until one day it doesn't start at all. A dirty coil or a clogged filter makes the system work harder to move the same amount of air. A compressor running against restricted airflow runs hotter than it should for longer than it should. Ice on the outdoor coil follows the same pattern. A unit that can't defrost properly keeps running with ice building up, and that ice blocks airflow further, so the system runs even longer trying to catch up. None of these start as compressor problems. They end as compressor problems because the system kept running instead of getting looked at.
A tech starts outside, checking whether the unit runs at all and whether the reversing valve shifts the system between heating and cooling the way it should. Gauges go on next to check the refrigerant charge against what the system should be doing. Inside, the panel comes off so the capacitor and contactor can be tested, since those parts take the brunt of wear from every start and stop the system makes. If the coil's iced over or the airflow feels weak, the tech traces that back to a dirty filter, a blocked return, or a defrost cycle that isn't working right. Most of this gets sorted out with a multimeter and a set of gauges before anything gets opened up or replaced.